Reservoir Monitoring
SADAR®-E
SADAR-E Real-time Subsurface Activity Detection
PRODUCT DETAILS
SADAR®-E is an event-driven, seismic-acoustic monitoring technology solution that classifies and locates subsurface events of interest, automatically and in real-time.
THE SADAR® ADVANTAGE
Leveraging compact, phased array processing, SADAR delivers greater range and accuracy via a reduced seismic data acquisition network. By including spatial processing into the analytic sequence, SADAR is able to detect, associate, locate, and identify events of interest in the presence of elevated noise and clutter.
FEATURES
- Persistent -Always on, always listening, always processing
- Real-time
- Timely information is actionable information resulting in informed decision making
- Highly Sensitive
- Greater Range
- Compact, phased arrays
- Spatial analytics enhance results and disassociate unwanted noise and clutter
- Improved locations with reduced uncertainty
- Reduced Surface Footprint
- Environmental and land owner upside
- Lower risk to lifecycle and maintenance costs
- User Interface Interactive Map Displays
- Array(s) location
- State-of-health status of individual SADAR arrays
- Detection, classification, and localization alerts
GeoRes S8 (Server)
19in Rack-Mount Chassis |
4U |
SADAR-E Array Line Support per Chassis |
8 |
SADAR-E Arrays per Line |
7 |
Operating Temperature |
-20°C to 60°C |
Input Voltage Power |
100-260 VAC, 10W |
Array Power Supplied via 450-05290-xx |
Passthrough |
Dimensions |
19 in (W) x 13.5 (D) x 7 in (H) 48.26 cm (W) x 34.29 cm (D) x 17.78 cm (H) |
Weight |
11 lbs/5 kg |
GS ONE Geophone
All parameters are specified at 25°C in the vertical position unless otherwise stated. |
||
GS-ONE | GS-ONE LF | |
Response Frequency | 10 Hz, ± 0.35 Hz | 5 Hz, ± 0.5 Hz |
Spurious frequency | 240 Hz Typical | 160 Hz Typical |
Distortion at Vertical* | 0.05% Typical | <0.10% Typical |
Sensitivity with 20 kΩ load | 2.00 V/in/s (78.7 V/m/s) Typical | 2.27 V/in/s (89.4 V/m/s) Typical |
Damping with 20 kΩ load | 0.70 Typical | 0.670 Typical |
DC resistance | 1800 Ω, ± 5% | 2450 Ω, ± 5% |
*Distortion Measured @ 12 Hz with 0.7 in/s Pk-Pk Velocity |
Digitization |
24-Bit Delta – Sigma |
Sample Rate |
0.5, 1, 2, 4 ms |
Preamplifier Gains |
0, 6, 12, 18, 24, 30, 36 dB |
Maximum Input Signal for Sensor |
26 mm/sec |
Equivalent Input Noise |
@ 2 ms sample rate 1.77 μmm/sec rms |
Gain Accuracy | Better than 1% |
Anti-alias Filter |
83% Nyquist |
Instantaneous Dynamic Range |
124 dB @ 2 ms sample interval |
Crossfeed Isolation |
>90 dB |