header_interior-pages banner_interior-pages-mobile

Reservoir Monitoring

SADAR®-E

SADAR-E Real-time Subsurface Activity Detection

PRODUCT DETAILS

SADAR®-E is an event-driven, seismic-acoustic monitoring technology solution that classifies and locates subsurface events of interest, automatically and in real-time.

THE SADAR® ADVANTAGE

Leveraging compact, phased array processing, SADAR delivers greater range and accuracy via a reduced seismic data acquisition network. By including spatial processing into the analytic sequence, SADAR is able to detect, associate, locate, and identify events of interest in the presence of elevated noise and clutter.

FEATURES

  • Persistent -Always on, always listening, always processing
  • Real-time
    • Timely information is actionable information resulting in informed decision making
  • Highly Sensitive
    • Greater Range
  • Compact, phased arrays
    • Spatial analytics enhance results and disassociate unwanted noise and clutter
    • Improved locations with reduced uncertainty
  • Reduced Surface Footprint
    • Environmental and land owner upside
    • Lower risk to lifecycle and maintenance costs
  • User Interface Interactive Map Displays
    • Array(s) location
    • State-of-health status of individual SADAR arrays
    • Detection, classification, and localization alerts
SADAR_image

GeoRes S8 (Server)

19in Rack-Mount Chassis

4U

SADAR-E Array Line Support per Chassis

8

SADAR-E Arrays per Line

7
Operating Temperature

-20°C to 60°C

Input Voltage Power

100-260 VAC, 10W

Array Power Supplied via 450-05290-xx

Passthrough
Dimensions

19 in (W) x 13.5 (D) x 7 in (H)

48.26 cm (W) x 34.29 cm (D) x 17.78 cm (H)

Weight

11 lbs/5 kg

GS ONE Geophone

All parameters are specified at 25°C in the vertical position unless
otherwise stated.
GS-ONE GS-ONE LF
Response Frequency 10 Hz, ± 0.35 Hz 5 Hz, ± 0.5 Hz
Spurious frequency 240 Hz Typical 160 Hz Typical
Distortion at Vertical* 0.05% Typical <0.10% Typical
Sensitivity with 20 kΩ load 2.00 V/in/s (78.7 V/m/s) Typical 2.27 V/in/s (89.4 V/m/s) Typical
Damping with 20 kΩ load 0.70 Typical 0.670 Typical
DC resistance 1800 Ω, ± 5% 2450 Ω, ± 5%
*Distortion Measured @ 12 Hz with 0.7 in/s Pk-Pk Velocity

 

Digitization

24-Bit Delta – Sigma

Sample Rate

0.5, 1, 2, 4 ms

Preamplifier Gains

0, 6, 12, 18, 24, 30, 36 dB

Maximum Input Signal for Sensor

26 mm/sec

Equivalent Input Noise

@ 2 ms sample rate

1.77 μmm/sec rms

Gain Accuracy  Better than 1%

Anti-alias Filter

83% Nyquist

Instantaneous Dynamic Range

124 dB @ 2 ms sample interval

Crossfeed Isolation

>90 dB

THD

<0.2%